General Frame Construction


Construction
Gauge 18, 16, 14, & 12
Material 1. Cold Rolled
2. A-60 and G-90
3. Stainless Steel
Corners Machine Mitred
Construction Options
(STD)NAAMM/HMMA 861:
SDI100, HMMA 860:
Face and Soffit Welded
Face Welded or Knockdown
Fill Welded
Hinge Reinforcement 7 GA X 1-1/4" X 10"
Strike Reinforcement 12 GA or equivalent # threads
Closer Reinforcements 12 GA
All Other Reinforcements 12 GA
Anchors 16, 14, 12 GA
Cold Rolled or Galvanized
Floor Clip 16, 14, 12 GA
Cold Rolled or Galvanized
Standard Primer (Gray) EPA Approved, Alkyd, Zinc Compound
Finish Options See Finish Options
Sound Deadening Sprayed Asphalt Coating Inside of Jambs
Fire Rating See Fire Rated
Bullet Resistant See Bullet Resistant

Frame Nomenclature


Frame Nomenclature

Minimum Frame Dimenstions


Minimum Frame Dimenstions